Logic lines
RoboPLC re-exports Logic Line crate which is a part of RoboPLC project.
Logic Line is a logic processing engine that combines the best of both worlds. Inspired by Ladder Logic, Monads and some others, it allows to write chains of logic rules as a regular Rust code, but provides built-in tools for state recording, debugging and visualization.
Note
To work with logic lines, enable roboplc crate logicline feature.
Contents
Working with logic lines
The logic state recording is disabled by default, to enable it, use:
roboplc::logicline::global::set_recording(true);
Processing logic:
use roboplc::logicline;
use rtsc::time::interval;
// Create a logic processor per thread
let mut processor = logicline::global::processor();
let mut system_on = false;
for _ in interval(Duration::from_millis(100)) {
processor
.line("line1_ok", sensors.temperature.as_f64())
.then_any(
action!(temperature_normal),
action!("voltage_critical", |_| {
not(voltage_critical(sensors.voltage.as_f64()))
})
)
.then(action!("ON", |()| {
system_on = true;
Some(())
}));
processor
.line("line1_w", sensors.temperature.as_f64())
.then(action!(temperature_critical))
.then(action!("voltage", |()| Some(sensors.voltage.as_f64())))
.then(action!(voltage_critical).with_recorded_input(&sensors.voltage.as_f64()))
.then(action!("OFF", |()| {
system_on = false;
Some(())
}));
logicline::global::ingress(&mut processor);
// process system_on variable, by synchronizing it with global program
// context or sending new value directly to equipment
Refer to the Logic Line documentation for more details.
Note
In production consider introducing API to switch the recording on for debugging or controling purposes, then switch it off when not required.
Exporting logic lines
Logic Line provides several ways to expose global project state:
// listen on 0.0.0.0:9001
roboplc::logicline::global::install_exporter()?;
The above example starts an HTTP server on the default address 0.0.0.0:9001 To start the server on a different address, refer to logic line crate documentation.
Warning
If the logic contains sensitive data, the access to the exporter server should be restricted, as an option, the server can be available for the local host only:
roboplc::logicline::global::install_exporter_on("127.0.0.1:9001").unwrap();
Viewing logic lines
If RoboPLC Manager is used, the logic lines global state can be viewed in its interface. The program logic lines exporter must be available on the host at the address http://127.0.0.1:9001.

The Logic Line crate also provides built-in UI, which can be enabled by:
cargo add logicline --features exporter-ui
When exporter-ui feature is enabled, the default interface is available at http://HOST:9001.
Schema notation